Shenzhen Chengtiantai Cable Industry Development Co.,Ltd

Chengtiantai Cable (CTT Cable)Since 1983

Manufacturer from China
Verified Supplier
8 Years
Home / Products / Copper Conductor Cable /

Single Core IEC 60502-1 Cables 600/1000V , Copper Conductor Electrical Cable XLPE Insulated Cables ( Unarmoured )

Contact Now
Shenzhen Chengtiantai Cable Industry Development Co.,Ltd
Visit Website
City:shenzhen
Province/State:guangdong
Country/Region:china
Contact Person:MsAnnie Chen
Contact Now

Single Core IEC 60502-1 Cables 600/1000V , Copper Conductor Electrical Cable XLPE Insulated Cables ( Unarmoured )

Ask Latest Price
Video Channel
Place of Origin :Shenzhen City, Mainland China
Brand Name :Chengtiantai cable
Certification :CE, CB
MOQ :Negotiable
Price :Negotiable
Packaging Details :Steel wooden Drum
Delivery Time :15 working days after payments
Model Number :YJV
Rated Voltage :0.6 / 1 kV
Conductor :Bear copper
No. of cores :Single core
Insulation :XLPE
Armoured Type :Unarmoured
Sheath :PVC Compound
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

IEC 60502-1 Single Core XLPE Insulated Cables

Applications of IEC 60502 XLPE Insulated Cable


IEC60502-1 XLPE Cable are used for electricity supply in low voltage installation system, IEC60502-1 XLPE Cables are suitable for installation in indoors and outdoors, in cable ducts, under ground, in power and switching stations, local energy distributions, industrial plants, where there is no risk of mechanical damage.

Construction of IEC60502-1 XLPE Cable

1. Conductors

The conductors shall be either of Class 1 or Class 2 of plain or metal-coated annealed copper or of plain aluminium or aluminium alloy, or of Class 5 of plain or metal-coated copper in accordance with IEC 60228.

2. Insulation

XLPE material and thickness shall be as per IEC 60502 or BS 5467 rated for 90°C continuous operation.

3. Assembly / Inner Covering

The inner coverings may be extruded or lapped. For cables with circular cores, except cables with more than five cores, a lapped inner covering shall be permitted only if the interstices between the cores are substantially filled. A suitable binder is permitted before application of an extruded inner covering. The material is compatible with the insulating material,The materials used for inner coverings and fillers shall be suitable for the operating temperature of the cable and compatible with the insulating material.For halogen free cables, the inner covering and fillers shall also be halogen free compound.

4. Armour

Aluminum/galvanized steel/steel wires applied helically over the Inner Covering as per IEC 60502-1, or double aluminum/steel tapes and copper/tinned copper wire can also be manufactured upon request.

5. Outer Sheath


Outer sheath shall be of extruded PVC Type ST1/ST2 as per IEC 60502-1, Polyethylene type ST3/ST7, Halogen free compound ST8, Polychloroprene, chlorosulfonated polyethylene or similar polymers, type SE1 are also available on request.

6. Fire Performance of Cable Sheaths


Cables can be supplied with special flame retardant PVC outer sheath to comply with the flame test requirements of IEC 60332-3-22, IEC 60332-3-23 and IEC 60332-3-24, Halogen Free material comply to IEC60754-1/2 and IEC 60684-2.

Physical and Electrical Characteristics of IEC60502-1 XLPE Cable:

No.cores x
cross-sec.
Insulation
thickness
Sheath
thickness
Nominal
value
Outer Ø
approx.
weight
approx.
Current ratings in air 30℃ Current ratings buried 20℃ maximum DC resistance at 20℃
mm² mm mm mm kg / km A A Ω/km
1×1.5 0.7 1.4 5.8 45 32 43 12.1
1×2.5 0.7 1.4 6.2 57 42 57 7.41
1×4.0 0.7 1.4 6.7 75 56 74 4.61
1×6.0 0.7 1.4 7.2 97 70 93 3.08
1×10 0.7 1.4 8.2 142 97 127 1.83
1×16 0.7 1.4 9.2 205 125 167 1.15
1×25 0.9 1.4 10.8 304 165 216 0.73
1×35 0.9 1.4 11.8 403 200 261 0.52
1×50 1.0 1.4 13.3 555 245 311 0.39
1×70 1.1 1.4 15.3 756 305 388 0.27
1×95 1.1 1.5 17.1 1005 375 461 0.19
1×120 1.2 1.5 18.7 1250 435 527 0.15
1×150 1.4 1.6 20.9 1561 500 592 0.12
1×185 1.6 1.6 22.9 1910 580 671 0.10
1×240 1.7 1.7 25.5 2453 685 781 0.08
1×300 1.8 1.8 28.2 3044 795 886 0.06
1×400 2.0 1.9 32.0 4024 930 1019 0.05
1×500 2.2 2.0 35.4 5006 1080 1170 0.04

IEC60502-1 XLPE Cable INSTALLATION METHOD DETAILS

Single Core IEC 60502-1 Cables 600/1000V , Copper Conductor Electrical Cable XLPE Insulated Cables ( Unarmoured ) Single Core IEC 60502-1 Cables 600/1000V , Copper Conductor Electrical Cable XLPE Insulated Cables ( Unarmoured ) Single Core IEC 60502-1 Cables 600/1000V , Copper Conductor Electrical Cable XLPE Insulated Cables ( Unarmoured ) Single Core IEC 60502-1 Cables 600/1000V , Copper Conductor Electrical Cable XLPE Insulated Cables ( Unarmoured )
A1 – Thermally insolated wall (Single-core) A2 – Thermally insolated wall (multi-core) B1 – Apparent electroduct (Single-core) B2 – Apparent electroduct (multi-core)
Single Core IEC 60502-1 Cables 600/1000V , Copper Conductor Electrical Cable XLPE Insulated Cables ( Unarmoured ) Single Core IEC 60502-1 Cables 600/1000V , Copper Conductor Electrical Cable XLPE Insulated Cables ( Unarmoured ) Single Core IEC 60502-1 Cables 600/1000V , Copper Conductor Electrical Cable XLPE Insulated Cables ( Unarmoured ) Single Core IEC 60502-1 Cables 600/1000V , Copper Conductor Electrical Cable XLPE Insulated Cables ( Unarmoured )
B1 – Electroduct in brickwork (Single-core) B1 – Electroduct in brickwork (multi-core) C – On the wall  C – On the ceiling
Single Core IEC 60502-1 Cables 600/1000V , Copper Conductor Electrical Cable XLPE Insulated Cables ( Unarmoured ) Single Core IEC 60502-1 Cables 600/1000V , Copper Conductor Electrical Cable XLPE Insulated Cables ( Unarmoured ) Single Core IEC 60502-1 Cables 600/1000V , Copper Conductor Electrical Cable XLPE Insulated Cables ( Unarmoured ) Single Core IEC 60502-1 Cables 600/1000V , Copper Conductor Electrical Cable XLPE Insulated Cables ( Unarmoured )
C – Non-perforated tray F – Perforated tray (Single-core) F – Perforated tray (multi-core) F –Suspended (Single-core)
Single Core IEC 60502-1 Cables 600/1000V , Copper Conductor Electrical Cable XLPE Insulated Cables ( Unarmoured ) Single Core IEC 60502-1 Cables 600/1000V , Copper Conductor Electrical Cable XLPE Insulated Cables ( Unarmoured ) Single Core IEC 60502-1 Cables 600/1000V , Copper Conductor Electrical Cable XLPE Insulated Cables ( Unarmoured ) Single Core IEC 60502-1 Cables 600/1000V , Copper Conductor Electrical Cable XLPE Insulated Cables ( Unarmoured )
E – Suspended (multi-core) B2 – Construction space B2 – Construction space B1 – Electroduct (Single-core)
Single Core IEC 60502-1 Cables 600/1000V , Copper Conductor Electrical Cable XLPE Insulated Cables ( Unarmoured ) Single Core IEC 60502-1 Cables 600/1000V , Copper Conductor Electrical Cable XLPE Insulated Cables ( Unarmoured ) Single Core IEC 60502-1 Cables 600/1000V , Copper Conductor Electrical Cable XLPE Insulated Cables ( Unarmoured ) Single Core IEC 60502-1 Cables 600/1000V , Copper Conductor Electrical Cable XLPE Insulated Cables ( Unarmoured )
B2 – Electroduct (Multi-core) B2 – Closed raceway embedded in floor (multi-core) B2 – Closed raceway embedded in floor (multi-core) B1 – Ventilated raceway embedded in floor
Single Core IEC 60502-1 Cables 600/1000V , Copper Conductor Electrical Cable XLPE Insulated Cables ( Unarmoured ) Single Core IEC 60502-1 Cables 600/1000V , Copper Conductor Electrical Cable XLPE Insulated Cables ( Unarmoured )
C – Embedded in the brickwork D – Buried in additional mechanical protection

Cable Drum Data

CABLE DRUMS D1=Flange Diameter(mm) W=Useful Width (mm) D2=Barrel Diameter(mm)
Single Core IEC 60502-1 Cables 600/1000V , Copper Conductor Electrical Cable XLPE Insulated Cables ( Unarmoured ) 1000 700 500
1100 700 550
1200 700 600
1400 750 710
1600 900 900
1800 1120 1000
2400 1150 1300

RECOMMENDED ORDERING PARAMETERS

CONTACT

For prompt quotation / supplies please make sure your inquiries and your orders are
securing the following data :

1 - International or Special Standard. (Alternatively, the precise usage of the cable.)
2 - Rated voltage.
3 - Copper or Aluminium conductors.
4 - Size of each conductor.
5 - Insulation material : XLPE or others.
6 - Number and identification of conductors.
7 - Other requirements.
8 - Packing.
9 - Required delivery time.
10 - Required validity.

If this all seems a litle too technical for you, then why not get in touch with us.

We look forward to assisting you in identifying the best products for your specific application and to answer any questions you might have.

Tel:+86 755 6114 5028
Fax:+86 755 61137976
E-mail : cttcable@hotmail.com
Head office:chengtiantai Industrial Park, Lisonglang community, Gongming office, Guangming district, Shenzhen P.R. China 518106

WARRANTY

For a period commencing on the date shipped the Goods to Buyer and continuing for a period of 12 months thereafter.

Inquiry Cart 0